Skip to content

Latest commit

 

History

History
98 lines (74 loc) · 5.04 KB

verification.md

File metadata and controls

98 lines (74 loc) · 5.04 KB

Verification and CI matrix

Theseus uses unit tests, integration tests, direct example smoke runs, and golden-data regressions. Passing one class does not replace another: integration tests exercise cross-component behavior, while golden tests protect established numerical output.

CI configurations

The quick and nightly workflows build two executables:

  • a Cartesian build used by the existing CTest suite, example smokes, and golden-data regressions;
  • an axisymmetric build configured with -DAXISYMMETRIC=ON for the complete axisymmetric integration suite below.

The axisymmetric integration tests are separate CI steps so a failure identifies the affected capability directly. Their CTest XML, CMake cache, and build logs are included in failure artifacts.

CI integration tests

CTest name Configuration and execution Required result
TimestepCFLIntegration Cartesian order-3 CNS cavity, one and two MPI ranks The initial variable timestep matches the independently calculated mapped advective-plus-viscous stability rate; serial and MPI timesteps agree. Fixed-DT reporting occurs at the configured check interval, and a final-time-shortened step reports a proportionally smaller actual CFL.
CheckpointRestartIntegration Axisymmetric Euler uniform flow, two MPI ranks, two cycles A restarted cycle produces byte-identical per-rank checkpoint state and ParaView output to an uninterrupted run. Metadata must contain the required format, state, geometry, MPI, and discretization fields and identify axisymmetric geometry.
AxisymmetricUniformFlowIntegration Exact Euler and CNS uniform axial flow, one and two MPI ranks Density and pressure remain at the exact values, conserved-integral changes remain negligible, and serial/MPI results agree.
AxisymmetricEntropyWaveConvergence Exact Euler entropy wave over three mesh levels Cylindrical L2 errors decrease and both observed convergence rates are at least 1.7.
AxisymmetricInviscidSphereIntegration Mach 2 Euler sphere, one and two MPI ranks Both runs complete with finite positive density and pressure, develop nonuniform density and pressure ranges, and agree in their final reported ranges within 1e-5 absolute tolerance.
AxisymmetricViscousSphereIntegration Mach 0.3, Re_D=100, order-3 CNS sphere, one and two MPI ranks The same positivity, body-flow-response, and serial/MPI agreement requirements as the inviscid sphere case.

The sphere tests accept the MFEM device selected by the CMake cache variable AXISYMMETRIC_TEST_DEVICE. CI currently tests cpu; CUDA and HIP are untested.

The viscous sphere test exercises the axisymmetric CNS body-flow path. It is not yet a quantitative validation of wake separation distance; that requires suitable subsonic characteristic boundaries, steady-state and mesh-convergence studies, and automated separation-point extraction.

Run the axisymmetric CI integration suite locally with:

ctest --test-dir build-axisymmetric \
  -R '^(Axisymmetric.*(Integration|Convergence)|CheckpointRestartIntegration)$' \
  --output-on-failure

Additional permanent axisymmetric tests

The complete axisymmetric CTest suite also includes:

  • AxisymmetryConfigTests: build/configuration, mesh, coordinate, and state contract checks;
  • AxisymmetricGeometryTests: cylindrical measure and inviscid/viscous source checks, including analytic axis limits;
  • AxisymmetricUniformFlowIntegration: exact Euler and CNS uniform axial flow in serial and two-rank MPI, with a configurable MFEM device;
  • AxisymmetricEntropyWaveConvergence: three mesh levels, decreasing cylindrical L2 error, and a minimum observed convergence rate of 1.7;
  • checkpoint/restart and sphere tests listed above.

Run all registered tests with:

ctest --test-dir build --output-on-failure
ctest --test-dir build-axisymmetric --output-on-failure

Direct CI smoke runs

These runs require successful completion and the configured NaN checks. They do not compare against reference fields.

Case Fixed timestep Maximum steps
Euler Isentropic Vortex 0.002 100
CNS Lid-Driven Cavity 0.0001 100
LTE Euler Vortex 1e-5 100

Regression comparisons

The cyclic Isentropic Vortex regression compares the first and last datasets in its ParaView collection for density, with atol=5e-5 and rtol=2e-6.

The golden-data regressions compare all available point fields and mesh topology at the specified output cycle:

Case Timestep Output cycle Absolute tolerance Relative tolerance
Isentropic Vortex 0.001 500 1e-13 1e-13
LTE Vortex 1e-5 200 1e-10 1e-10
Lid-Driven Cavity 0.0001 4000 1e-12 1e-12
Taylor-Green Vortex 2D 0.0001 100 1e-13 1e-13
Forward-Facing Step 0.0001 100 3e-13 1e-13

The workflow files are the executable source of truth for CI commands. Update this matrix whenever a case, step count, tolerance, build configuration, or required assertion changes.