Adapter doctor: is this dongle dying?

A Realtek adapter can be electrically dead-ish and still look fine: it enumerates, USB transfers are clean, driver init completes green — and the radio is stone-deaf. Measured on a degrading RTL8812AU (#205), the failure lives in places no "did init succeed" check reaches:

  • EFUSE reads return stochastic garbage — a different EEPROM ID / calibration map on every physical read. The driver then configures the wrong RFE / PA / LNA tables and the radio hears nothing. A healthy chip returns byte-identical maps every read, cold or warm.
  • The MCU never boots firmware — the download checksum report never asserts. On Jaguar1 that is deliberately non-fatal (monitor RX runs without the 8051), so nothing aborts.
  • The failure drifts: the same unit alternates between garbage EFUSE, stable-but-wrong reads, and valid-ID-but-still-dead phases. Any single-symptom check misses some phase; probing independent subsystems catches every one.

doctor (examples/doctor) runs the battery and grades it:

build/doctor                       # first Realtek adapter, ambient traffic
build/doctor --pid 0x8812 --channel 6 --expect-traffic
build/doctor --bus 3 --port 2.3.3  # topology select (two same-PID adapters)
  1. Bring-upInitWrite; an abort is an immediate FAILING.
  2. EFUSE stability — N fresh physical map reads (IRtlRadio::ProbeEfuseStability), cross-compared byte-for-byte + EEPROM-ID (0x8129) validated. Any read-to-read mismatch is conclusive by itself. Not probed on the 8822E — its OTP is not reliably readable after bring-up by design, so probing would flag healthy units. Realtek-only (IRtlRadio): on another radio doctor skips this step and grades the remaining legs.
  3. FW boot — checksum + MCU-ready outcome of the bring-up's download (IRadio::GetFwBootStatus).
  4. RX smoke — FCS-clean frame count over --listen-secs. Ambient traffic counts. Hearing nothing is only SUSPECT unless --expect-traffic vouches for a source on the channel — an RF-quiet room is otherwise indistinguishable from a deaf radio (same trap as performance benchmarking).

Verdict → exit code: HEALTHY=0, SUSPECT=1, FAILING=2 (3 = tool / open error), plus a doctor.verdict machine event and per-reason text. The classifier is pure logic (src/AdapterHealth.h, ctest'd in tests/adapter_health_selftest.cpp); grading rules and their rationale live next to the code.

Getting a definitive verdict

One warm run can miss a cold-only pathology (the #205 unit read valid EFUSE on some warm passes while staying deaf). For a hard verdict, give the doctor per-rep true cold + vouched traffic:

sudo bash tests/adapter_doctor_cold.sh <hub> <hubport> <sysfs> <bus> <portpath> [reps]
# bench example — suspect unit on nested smart-hub port 3-2.3.3:
sudo bash tests/adapter_doctor_cold.sh 3-2.3 3 3-2.3.3 3 2.3.3 3

Per rep the wrapper VBUS-cycles the DUT's uhubctl-switchable hub port, keeps the in-tree rtw88 module away (temp blacklist — udev reloads it on every re-enumeration otherwise, and its probe firmware-download would contaminate first-touch), runs a radiation-verified beacon flood, and invokes doctor --expect-traffic. Exit code is the worst verdict across reps.

A MediaTek DUT takes three env knobs the Realtek default does not need: DOCTOR_RTW88_MOD=mt76x2u (the module to keep away), DOCTOR_DUT_VID=0x0e8d DOCTOR_DUT_PID=0x7612 (the doctor's default PID walk is Realtek-only), and DOCTOR_MT7612U_FW_DIR=<dir> holding the decompressed mt7662.bin + mt7662_rom_patch.bin (passed to the doctor as --mt7612u-fw-dir, since the doctor reads no environment). The EFUSE leg reports "not probed" there (IRtlRadio-only) and the FW leg reports fw_attempted=0 because the backend does not surface GetFwBootStatus; the verdict rests on bring-up and the RX smoke.

Validated on the bench pair: the healthy unit grades HEALTHY (stable 0x8129 EFUSE ×4, FW ready, thousands of frames) and the dying unit grades FAILING on every cold rep — regardless of which face the sickness shows that day (garbage EFUSE, or valid-ID-with-dead-MCU + deaf-to-flood).

Reading a SUSPECT

  • heard nothing (no traffic guarantee) — re-run with a known traffic source on the channel and --expect-traffic.
  • EFUSE is blank (autoload fail) — all-0xFF map. Legitimate on some bare dev boards; on a retail adapter it means the calibration data is gone.
  • MCU never booted firmware alone — can be a transient warm-state hang (the vendor drivers retry this too). VBUS power-cycle and re-run; persistent across cold reps = hardware.

A cheap independent cross-check on any modern kernel: the in-tree rtw88 driver's probe (dmesg) fails with failed to validate firmware on a unit with this pathology and binds cleanly on a healthy one.