Local service diagnostics and shutdown

The service writes one JSON object per diagnostic line to stderr. It uses the existing JSON serializer; no logging runtime dependency or user-configurable verbose HTTP logging is added. Do not redirect debug output from HTTP clients or add raw errors/configuration to these events.

request_complete contains only:

  • requestId: a generated process-local numeric identifier, also returned as x-request-id; incoming request IDs are ignored.
  • method: one standard allowlisted HTTP method or OTHER.
  • route: an allowlisted static route template, such as /api/v1/definitions/{name}, or unmatched.
  • status: HTTP status code.
  • durationMs: elapsed handler time in milliseconds.

Bodies, headers, raw paths, query strings, definition names, operation IDs, credentials, provider response bodies and database paths are not recorded. Request IDs restart when the process restarts and are diagnostic references, not authentication tokens. A completion event measures response construction; it does not prove a client received the full body or that a guest is ready. Requests aborted before response construction may have no completion event.

Lifecycle events are server_listening (numeric loopback port), server_drain_timed_out (no fields), server_stopped, and server_failed (a fixed application-owned stage code). A failure exits with code 1 without printing the underlying error or user-supplied configuration. Useful failure codes include:

Reason Inspect locally
invalid_port_configuration VMANYWARE_PORT range/encoding
invalid_provider_configuration Explicit provider variables and trusted CA
invalid_template_configuration Explicit catalog path and documented schema
invalid_database_configuration Database setting is nonempty and valid
database_lock_unavailable Another process owns the same database, or path permissions
database_unavailable Database access and supported schema
listener_unavailable Selected local port is free
operation_recovery_failed Database accessibility during recovery
shutdown_signal_unavailable OS signal registration
operation_worker_stopped_unexpectedly Worker/database health; restart and inspect recovered job status
server_stopped_unexpectedly Local HTTP listener/runtime failure

On Unix, SIGINT and SIGTERM are registered before readiness is announced and both request Axum graceful shutdown. Active requests have up to five seconds to drain. If an unfinished request prevents completion, the service emits the fixed server_drain_timed_out event, aborts its inventory worker and returns from the server runtime; remaining async connections close during runtime teardown. An idle service exits immediately. The service releases its database lock on exit. Running records remain durable and become interrupted on the next exclusive startup; queued work remains queued. There is no provider-task cancellation or VM cleanup. A requested shutdown exits zero even if the drain deadline expires; server_stopped means the process is stopping, not that every request completed. This bounds HTTP draining, not arbitrary blocking OS/database I/O. Windows Ctrl-C handling is prepared in source but has not been compiled or run on Windows.

Actual subprocess tests on macOS verify redaction, generated IDs, unknown routes and methods, SIGTERM/SIGINT exit status zero and restart with the same database. An additional subprocess test keeps a request body unfinished through SIGTERM, observes the five-second timeout event/exit, verifies socket closure and restarts with the same database/port. Idle SIGINT must still exit in under two seconds. Tests use an empty process environment and temporary database, with no provider.

Implementation references: Axum middleware, Tokio Unix signals.