Test cases for DML simulation development
Here are files to test DML simulators.
For each test cases, 3 files are provided :
- XXXX.txt : case parameters (see below)
- EFR_XXXX.txt : SPL at 1m measured with REW (panel in open back condition)
- Z_XXXX.txt : electrical impedance measured with REW
Warning : the SPL are from indoor measurements. The measurements were checked free of room reflection before 5ms (200Hz).
- Isotropic materials :
- EPS : Expended Polystyrene
- PMMA : Acrylic
- Orthotropic materials :
- PWD5 : Poplar plywood (3 cases with various boundary conditions, exciter positions)
note : plate dimensions LXMM, LYMM in mm, other in SI units
- CASETITLE = short description
- BCOND = boundary conditions (S simply supported, C clamped, F free edge), North (top), West (left), South (bottom), East (right)
- LXMM = x axis (horizontal) plate dimension in mm (North and South edge)
- LYMM = y axis (vertical) plate dimension in mm (West and East edge)
- H = plate thickness in m
- EX = x axis Young Modulus in Pa
- EY = y axis Young Modulus in Pa
- GXY = shear modulus in Pa
- RHO = density in kg/m³
- NUX = x axis Poisson's ratio
- NUY = y axis Poisson's raitio
- ZETAMD = modal damping coefficient (=1/2Q, Q modal quality factor)
- EXTMODEL = exciter model
- POSX = x axis exciter position (decimal value from 0 = full West to 1 = full East)
- POSY = y axis exciter position (decimal value from O = full North to 1 full South)