Improving CNN performance using GradCAM (Collab)
Doubt: Unexpectedly high classical performance metrics (AUC, F1, Acc) of compact CNNs (< 150M parameters) on small (~5k X-rays) Pneumonia Dataset.
Hypothesis: Possible model overfitting on unwanted features rather than the target pathology, Pneumonia.
Improving Convolutional Neural Network classification and feature localisation for Pneumonia Chest X-rays in the scenario of a lack of extensive annotated data and access to extensive GPU Training architectures.
-
Developed a model-independent, self-sufficient and recursive optimisation framework for CNN models utilising Gradient Class Activation Maps (GradCAMs), to tackle challenges of limited data and suboptimal localisation by iteratively augmenting and re-using the original dataset.
- GradCAM, like heatmaps, are used to visualise regions of the input image which strongly influence the model's classification output.
- Trained a compact CNN (~100M parameters) on a small dataset (~4.5k X-rays) that achieved high accuracy and F1 score, but showed poor pathology localisation when analysed using Grad-CAMs.
- Iteratively enhanced the dataset by overlaying Grad-CAMs from high-confidence predictions onto input images to highlight pneumonia-relevant regions, creating a refined dataset for model fine-tuning.
- Repeated the process to progressively improve localisation, producing models that better identified disease-relevant regions with each cycle.
Details
- Code: Pytorch | Data-set: paultimothymooney.
- After opening the notebook in Collab, please go to
File > Save as copy in Google Driveto experiment with the code after reading the Data Handling section below.
- .zip file containing the Pneumonia Dataset must be uploaded to the
My Drivefolder of the Google Drive mounted to the collab notebook. - .zip file is** automatically extracted** to
drive\My Drive\ML Data Setswhile removing any corrupted images. - To use external data-sets, place them in
drive\My Drive\ML Data Setsand change variable names.
- Baseline model architecture: TinyVGG
- Links to .pth weights of the trained models can be found in the
modelsfolder. - popular pre-trained architectures (VGG-16, VGG-19, ResNet-50, ResNet-101, ResNet-152) can be used and corresponding models loaded.
- Model, optimizer & scheduler state_dicts can be saved to Google Drive (
drive\MyDrive\ML Models\<xyz.pth>). These can be loaded in future for seamless resumption of progress.
mismatch in model parameters while loading models can be a result of modified architecture in the code
Details
- Implemented GradCAM functionality to check Pneumonia localisation of baseline and pre-trained models.
- Identified and optimised the optimal model architecture.
-
Test Loss: 0.305 | Test Acc: 88.28% | Sensitivity: 91.79% | Specificity: 81.62%
-
Problem: Focus on unwanted features, extremely poor localisation of Pneumonia. Heavy overfitting.

Pneumonia Class | Goodhere "Good" means prediction score >= 85%
blank boxesindicate wrong predictions
-
Test Loss: 0.362 | Test Acc: 83.91% | Sensitivity: 88.72% | Specificity: 75.07%
-
Progress: Improved but unsatisfactory localisation.
-
Test loss: 0.369 | Test acc: 83.59% | Sensitivity: 95.38% | Specificity: 62.82%
-
Progress: Improved localisation after adding FC layer with 10k params.
-
Test Loss: 0.379 | Test acc: 84.69% | Sensitivity: 93.33% | Specificity: 70.09%
-
Progress: Similar/worse localisation compared to ResNet-101 with similar evaluation metrics.
-
There is an unwanted focus on void regions surrounding the skeleton.
-
To fix this, a small centre crop was added to training images before feeding them to the model, thus preventing the model from "learning" these void regions.
-
Finally, ~17M parameters were re-trained** from scratch (~38% of ResNet-101) using above cropped train data** to achieve the current "best" model:
ResNet-101_GradCAM_Cropped_v4.pth -
Test Loss: 0.264 | Test Acc: 91.56% | Sensitivity: 94.62% | Specificity: 85.90% -
Progress: Obtained noticeable improvement in Pneumonia localisation and evaluation metrics.
The model is now ready to create an enhanced data set.
Details
- Train Data enhanced by overlaying accurate GarCAMs.
- Re-trained previously "un-frozen" ~17M ResNet-101_GradCAM_Cropped_v4.pth params using above enhanced data set.
-
One cycle resulted in a ~15% improvement in the localization of pneumonia, with only a ~3% decrease in test accuracy with respect to ResNet-101_GradCAM_Cropped_v4.pth.
-
Test Loss: 0.397 | Test acc: 88.59% | Sensitivity: 86.41% | Specificity: 91.88%
-
Details
- We can successfully develop a workaround for the limited data constraint to iteratively obtain better localisation & identification of pneumonia.
- During this process, as expected, test accuracy takes a small hit as the model diverges away from unwanted "easy" to detect features.
-
Model was not trained on annotated data; the presence of arrows pointing to Pneumonia in the X-rays makes no difference in the model choice
-
Post-fine-tuning the model on enhanced data, we observe significantly better localisation of Pneumonia to the lungs.
-
The model also relies less on unwanted features and void regions while predicting.
-
The results are limited to only one cycle shown in the schematic above; further process iterations are bound to yield gradual but better results.
- GradCAM - JimEverest
- Lung Segmentation - IlliaOvcharenko's repo