Motivtion

Doubt: Unexpectedly high classical performance metrics (AUC, F1, Acc) of compact CNNs (< 150M parameters) on small (~5k X-rays) Pneumonia Dataset.
Hypothesis: Possible model overfitting on unwanted features rather than the target pathology, Pneumonia.

Problem Statement

Improving Convolutional Neural Network classification and feature localisation for Pneumonia Chest X-rays in the scenario of a lack of extensive annotated data and access to extensive GPU Training architectures.

Approach

  • Developed a model-independent, self-sufficient and recursive optimisation framework for CNN models utilising Gradient Class Activation Maps (GradCAMs), to tackle challenges of limited data and suboptimal localisation by iteratively augmenting and re-using the original dataset.

    • GradCAM, like heatmaps, are used to visualise regions of the input image which strongly influence the model's classification output.
    • Trained a compact CNN (~100M parameters) on a small dataset (~4.5k X-rays) that achieved high accuracy and F1 score, but showed poor pathology localisation when analysed using Grad-CAMs.
    • Iteratively enhanced the dataset by overlaying Grad-CAMs from high-confidence predictions onto input images to highlight pneumonia-relevant regions, creating a refined dataset for model fine-tuning.
    • Repeated the process to progressively improve localisation, producing models that better identified disease-relevant regions with each cycle.

    image Image depicting one aforementioned cycle

 

INSTRUCTIONS

Details

General

  • Code: Pytorch | Data-set: paultimothymooney.
  • After opening the notebook in Collab, please go to File > Save as copy in Google Drive to experiment with the code after reading the Data Handling section below.

Data Handling

  • .zip file containing the Pneumonia Dataset must be uploaded to the My Drive folder of the Google Drive mounted to the collab notebook.
  • .zip file is** automatically extracted** to drive\My Drive\ML Data Sets while removing any corrupted images.
  • To use external data-sets, place them in drive\My Drive\ML Data Sets and change variable names.

CNN Models

  • Baseline model architecture: TinyVGG
  • Links to .pth weights of the trained models can be found in the models folder.
  • popular pre-trained architectures (VGG-16, VGG-19, ResNet-50, ResNet-101, ResNet-152) can be used and corresponding models loaded.
  • Model, optimizer & scheduler state_dicts can be saved to Google Drive (drive\MyDrive\ML Models\<xyz.pth>). These can be loaded in future for seamless resumption of progress.

mismatch in model parameters while loading models can be a result of modified architecture in the code


 

RESULTS FOR VARIOUS ARCHITECTURES

Details

Initial testing for Pneumonia localisation

  • Implemented GradCAM functionality to check Pneumonia localisation of baseline and pre-trained models.
  • Identified and optimised the optimal model architecture.

Different Architectures

TinyVGG CNN_GradCAM_v1.pth

  • Test Loss: 0.305 | Test Acc: 88.28% | Sensitivity: 91.79% | Specificity: 81.62%

  • Problem: Focus on unwanted features, extremely poor localisation of Pneumonia. Heavy overfitting.

    Grid of GradCAMs
    Pneumonia Class | Good here "Good" means prediction score >= 85%
    blank boxes indicate wrong predictions

VGG-16 VGG-16_GradCAM_v2.pth

  • Test Loss: 0.362 | Test Acc: 83.91% | Sensitivity: 88.72% | Specificity: 75.07%

  • Progress: Improved but unsatisfactory localisation.

    Grid of GradCAMs

ResNet-101 ResNet-101_GradCAM_v1.pth

  • Test loss: 0.369 | Test acc: 83.59% | Sensitivity: 95.38% | Specificity: 62.82%

  • Progress: Improved localisation after adding FC layer with 10k params.

    Grid of GradCAMs

ResNet-152 ResNet-152_GradCAM_v1.pth

  • Test Loss: 0.379 | Test acc: 84.69% | Sensitivity: 93.33% | Specificity: 70.09%

  • Progress: Similar/worse localisation compared to ResNet-101 with similar evaluation metrics.

    Grid of GradCAMs

Best Overall Localisation and Performance: ResNet-101 ResNet-101_GradCAM_v1.pth

  • There is an unwanted focus on void regions surrounding the skeleton.

  • To fix this, a small centre crop was added to training images before feeding them to the model, thus preventing the model from "learning" these void regions.

    Grid of GradCAMs

Optimizing ResNet-101_GradCAM_v1.pth

  • Finally, ~17M parameters were re-trained** from scratch (~38% of ResNet-101) using above cropped train data** to achieve the current "best" model: ResNet-101_GradCAM_Cropped_v4.pth

  • Test Loss: 0.264 | Test Acc: 91.56% | Sensitivity: 94.62% | Specificity: 85.90%

  • Progress: Obtained noticeable improvement in Pneumonia localisation and evaluation metrics.
    The model is now ready to create an enhanced data set.


    GradCAMs showing improved localisation


 

ENHANCED DATASET RESULTS

Details

Enhanced Data Set

  • Train Data enhanced by overlaying accurate GarCAMs.
    • "enhanced" - important features emphasised (in "white") while the rest of the image is suppressed.

    • "accurate" - The assumption is that GradCAMs localised to the lung are fairly accurate.


      Image showing 49 images from the enhanced train data
      post data transformations

Results using Enhanced Data Set ResNet-101_GradCAM_Cropped_v4_enh_v1.pth

  • Re-trained previously "un-frozen" ~17M ResNet-101_GradCAM_Cropped_v4.pth params using above enhanced data set.
    • One cycle resulted in a ~15% improvement in the localization of pneumonia, with only a ~3% decrease in test accuracy with respect to ResNet-101_GradCAM_Cropped_v4.pth.

    • Test Loss: 0.397 | Test acc: 88.59% | Sensitivity: 86.41% | Specificity: 91.88%


      Improved GradCAMs post fine-tuning using enhanced data


 

CONCLUSION

Details

Summary

  • We can successfully develop a workaround for the limited data constraint to iteratively obtain better localisation & identification of pneumonia.
  • During this process, as expected, test accuracy takes a small hit as the model diverges away from unwanted "easy" to detect features.

Results on annotated images

  • Model was not trained on annotated data; the presence of arrows pointing to Pneumonia in the X-rays makes no difference in the model choice

  • Covid-19 Pneumonia X-ray

  • Pneumonia X-ray

  • Pneumonia X-ray

Post and Pre-Enhanced Data Fine-Tuning Comparison

  • Post-fine-tuning the model on enhanced data, we observe significantly better localisation of Pneumonia to the lungs.

  • The model also relies less on unwanted features and void regions while predicting.

  • The results are limited to only one cycle shown in the schematic above; further process iterations are bound to yield gradual but better results.


    Final Comparison on the same 100 test images


 